Lifecycle & Support Services

Maintenance & support, 24/7 with a 4-hour on-site SLA.

Planned preventative maintenance, 24/7 emergency breakdown response with 4-hour on-site SLA on Critical-tier sites, leak detection and statutory compliance inspections. Across medical gas, industrial gas, LPG, hot water and steam boiler plant.

Technician inspecting industrial gas valves and pressure gauges
Boiler plant maintenance inspection in progress
Operational environment

Live-plant maintenance on a 400-bed regional medical facility, performed without disruption to clinical operations.

support_agent

24/7 emergency response

Round-the-clock technical hotline and on-site response for critical breakdowns, backed by SLA-driven response times.

verified

SANS 347 / SAQCC

Pressure equipment regulation, SAQCC Gas registered inspectors and full statutory compliance sign-off.

Service level agreements

event_repeat Tier 01 · Essential

Preventative maintenance

Scheduled inspections to keep plant performing reliably and within manufacturer specification.

  • Quarterly site visits
  • Functional & safety checks
  • Consumable replacement
  • Service report & logbook
  • Business-hours support
Best for: low-risk sites Enquire arrow_forward
emergency Tier 03 · Critical

24/7 critical response

Guaranteed response times for life-critical and revenue-critical plant where downtime is not an option.

  • Monthly site visits
  • 4-hour on-site SLA
  • 24/7 engineering hotline
  • Critical spares on consignment
  • Boiler attendant on retainer
Best for: ICU / production Enquire arrow_forward

Compliance & inspection matrix

Statutory & recommended service frequency

Discipline Critical Actions Frequency Deliverable Status
Medical Gas Pipeline Purity, leak & pressure-drop testing; alarm verification Quarterly SAQCC-signed audit log Critical
Steam & Hot Water Boilers External inspection, safety valve test, water analysis Monthly / Annually PER & SANS 347 certificate Mandatory
Pressure Vessels External & internal inspection, ultrasonic thickness Bi-annual / 5-Yearly Approved inspector report Mandatory
LPG & Bulk Gas Leak survey, regulator service, ESD function test Annually SANS 10087 compliance cert Critical
Calibration & Instrumentation Gauge & transmitter calibration; BMS verification Annually Calibration certificates Recurring
Boiler Attendant Daily plant operation, log-keeping & routine checks Daily (On Retainer) Operations & incident log Recurring

What’s covered

sensors

Leak detection

Electronic leak detection across medical gas reticulation, LPG storage and industrial gas pipelines, with documented loss reports.

tune

Calibration & recertification

Pressure gauges, transmitters, safety valves and BMS instrumentation calibrated by SAQCC Gas registered technicians.

construction

Breakdown repairs

Rapid mobilisation for emergency breakdowns. From manifold failures and pump replacements to burner fault diagnosis.

verified_user

Statutory compliance

Pressure Equipment Regulation (PER), SANS 347, SANS 10087, SANS 10166 and ISO 7396-1 audits and remedial work.

water_drop

Water treatment

Boiler feedwater analysis, chemical dosing and softener service to protect heat-exchange surfaces and extend plant life.

engineering

Boiler attendant

Qualified Category B boiler attendants on retainer for sites that require daily operation, log-keeping and safety oversight.

inventory_2

Critical spares

On-consignment spare-parts stockholding for high-risk sites: burners, valves, sensors and manifold components.

analytics

Plant reporting

Digital service reports, asset registers and trend analysis to inform capital planning and predictive replacement schedules.

Plant we maintain

One contract, one engineering team across every discipline. Inspection frequency tagged on each card.

Medical gas pipelines under maintenance medical_services

Medical gas pipelines

Purity, leak and pressure-drop testing, alarm verification, manifold and outlet service.

Quarterly + 24/7 hotline
Industrial gas plant maintenance factory

Industrial gas plant

Manifold service, regulator overhaul, NDT weld inspection and pressure-test recertification.

Bi-monthly typical
LPG bulk installation maintenance propane_tank

LPG bulk installations

Leak survey, regulator service, ESD function test and SAQCC Gas Certificate of Conformity renewal.

Annually (SANS 10087)
Steam boiler maintenance heat_pump

Steam boilers

External inspection, safety valve test, water analysis, burner service and statutory PER inspection.

Monthly + annual
Hot water plant maintenance water_heater

Hot water plant

Calorifier service, anti-Legionella verification, pump and circulation loop checks, BMS calibration.

Quarterly typical
Pressure vessel inspection compress

Pressure vessels

External and internal inspection, ultrasonic thickness testing, approved-inspector reporting.

Bi-annual / 5-yearly
Calibration and instrumentation tune

Calibration & instrumentation

Gauge and transmitter calibration, BMS verification, traceable certificates issued on every service.

Annually
swipe Drag or swipe to see more plant categories

Accreditations

SAQCC Gas

Registered Gas Practitioners on every service visit. Certificates of Compliance and Conformity issued for statutory and insurer sign-off.

LPGSA Member

LP Gas Safety Association of Southern Africa member in good standing. LPG service work meets the LPGSA Code of Practice.

CIDB Registered

Construction Industry Development Board registered. Eligible for public-sector maintenance contracts and tender lists.

BEE Level 1

Verified Level 1 B-BBEE contributor. 135% procurement recognition for our clients.

When uptime is non-negotiable

Engineered for the unthinkable

In critical-care wards, mining process plants and production lines, downtime carries unacceptable cost. Our maintenance contracts are built around redundancy, fast failover and engineering accountability, not paperwork.

  • check_circle4-hour on-site SLA on Critical-tier sites
  • check_circleAutomatic manifold changeover monitoring
  • check_circleEmergency shutdown (ESD) integration
  • check_circleAnnual statutory compliance audit included
  • check_circleSingle accountable contract, one engineering team
Medical gas control panel inspection
Technician inspecting industrial pressure gauges

Need an SLA, an emergency call-out or a one-off compliance audit?

New service plans typically scoped within 5 working days of enquiry. Emergency response is 24/7, with a 4-hour on-site SLA on Critical-tier sites.

phone_in_talk 24/7 Engineering Hotline · 0861 764 269